S95.3U02 / S95.3U12 HART®
  • Free programmable universal temperature transmitter with 4mA…20mA digital output and HART ® signal,
  • standard version S95.3U2,
  • EEx(i) version S95.3U12 for installation in hazardous area,
  • 2-wire head transmitter,
  • wide range of inputs such as Pt100, Pt1000, Ni100, Ni1000, T/C types B, E, J, K, L, N, R,S,T,U as well as resistance and voltage inputs,
  • programmable via interface and Smart Vision Software or hand held terminal,
  • customer specific linearization, continuous sensor and self monitoring,
  • Electrical isolation I/O
  • EMC acc. EN 50082-2 and NE21,
  • fits standard DIN B-head,
  • high accuracy and reliability

Description

  • Compact size head transmitter
  • Easy-to-configure with Smart-Vision Software assistance and PC-Interface,
  • rescaling in field via lap-top computer possible,
  • programmable zero adjustment and linearization as well as information or tag-no,
  • versatile utilization because of huge range of inputs,
  • shock resistant plastic housing, sealed electronics
  • very resistant to electromagnetic fields and line bursts
  • Off-the-shelf availability non configured or factory configured
  • S93.3U12 meets ATEX requirements Ex II G EEx [ia] ib IIC T6 (<50°C), mount in zone 1

for data sheet, click on:
S95.3Ux2 HART®

 

S20 image